Series LLC

Advantages:

  • Energy efficiency class.
  • Improved circulation of airflow.
  • Powerful operation.
  • 2 programming options (Day, Sleep).
  • Corresponds to cooling operation at -10°C.
  • Heating operation at -15 °C outdoor air temperature.
  • Economy operation.
  • Programmable timer .
  • Super quiet operation.

 

Price

ASHG-LLCC / AOHG-LLCC

09LLCC 12LLCC
All prices are inclided VAT and excluded installation costs.

BGN

979.00 1.038,-

All prices are inclided VAT and excluded installation costs.

Technical data:

Efficiency data

ASHG-LLCC / AOHG-LLCC

09LLCC 12LLCCC
Cooling capacity Min./Nom./Max.

kW

2.5 (0.9-3.0) 3.4 (0.9-3.8)
Heating capacity Min./Nom./Max.

kW

3.0 (0.9-3.8) 4.0 (0.9-5.0)
Seasonal efficiency
(сaccording to EN14825)
Cooling Energy efficiency class A++ A++
SEER 6.90 6.60
Annual energy consumption

kWh

127 180
Heating (Average climate) Energy efficiency class A+ A
SCOP/A 4,00 3.80
Annual energy consumption

kWh

805 1,179

Technical data - Indoor unit

ASHG-LLCC

ASHG09LLCC ASHG12LLCC
Dimensions Unit (HeightxWidthxDepth)

mm

262×820×206 262×820×206
Weight Indor/Outdoor

kg

7.0/24 7.0/24
Sound pressure level  Cooling / Heating

dBA

43/38/33/22
43/38/33/22
43/38/33/22
43/38/33/22

Technical data - Outdoor unit

AOHG-LLCC

AOHG09LLCC AOHG12LLCC
Dimensions Unit (HeightxWidthxDepth)

mm

535×663×293 535×663×293
Sound pressure level  Cooling / Heating

dBA

47/48 50/51
Operation range Cooling
(Ambient Min.~Max.)

°CDB

-10~43 -10~43
Heating
(Ambient Min.~Max.)

°CWB

-15~24 -15~24
Refrigerant *Type/Charge kg-TCO₂Eq/GWP R410A/0,65/2,088 R410A/0,85/2,088

 

Funcitons:

  1. Sleep timer
    The sleep timer function automatically corrects the temperature thermostat setting according to the time setting to prevent excessive cooling or heating while sleeping.  
  2. Powerful operation
    Reach the setting temperature quickly.
  3. Automatic mode change
    Climate systems automatically change operating modes (between heating and cooling) depending on the set temperature and room temperature.
  4. Adjust flaps up / down
    The valves can automatically move up and down.
  5. Automatic fan speed
    The microcomputer automatically adjusts the airflow to effectively follow the changes in room temperature.
  6. Automatic restart
    In the event of a temporary power outage, the air conditioner will automatically restart in the previous mode once it is restored power supply.
  7. Program timer 
    The program timer operates the on and off timer once within a 24-hour period.
  8. Filter indicator
    Indicates the need to clean the filter with a light indicator.
  9. Washable panel
    Because the front panel is easy to remove, maintenance is also easy.
  10. All DC models
    High-efficiency DC inverter processor, enabling higher energy efficiency than conventional compressors.
  11. i-PAM controlled models
    Loss-reducing technology by precisely regulating the shape of the stress curve to a better sinusoid.