Series FAIRY

Advantages:

  • G10 inverter (minimum rotation speed 15Hz);
  • Cold plasma generator;
  • Cooling: -15°C~+43°С, Heating: -22°C~+24°C;
  • Electrical heater at the compressor crankcase and at drain tray;
  • Built in Wi-Fi adapter;
  • Controlling element: Electronic TRV;
  • Timer;
  • Warm start;
  • Self-diagnosis;
  • Indoor unit`s seven steps fan;

 

Price GWH09ACC-K6DNA1A GWH12ACC-K6DNA1D GWH18ACD-K6DNA1D GWH24ACE-K6DNA1A
Unit price (indoor unit + outdoor unit + remote control)

BGN

881,00 954,00 1 530,00 1 762,00

All prices are inclided VAT and excluded installation costs.

Technical data:

Efficiency data GWH09ACC-K6DNA1A GWH12ACC-K6DNA1D GWH18ACD-K6DNA1D GWH24ACE-K6DNA1A
Cooling capacity Min./Nom./Max.

kW

2,7 3,5 (0,7 – 4,0) 5,2 (1,26 – 6,6) 7,0 (1,93 – 8,85)
Heating capacity Min./Nom./Max.

kW

3,0 3,67 (0,8 – 4,5) 5,3 (1,12 – 6,8) 7,4 (1,8 – 10,63)
Seasonal efficiency
(сaccording to EN14825)
Cooling Energy efficiency class A++ A++ A++ A++
SEER 6,8 7,0 7,0 6,5
Annual energy consumption

kWh

- - - -
Heating (Average climate) Energy efficiency class A+ A+ A+ A+
SCOP/A 4,1 4,0 4,0 4,0
Annual energy consumption

kWh

- - - -
Technical data - Indoor unit GWH09ACC GWH12ACC GWH18ACD GWH24ACE
Dimensions Unit (HeightxWidthxDepth)

mm

889×294×212 889×294×212 1013×307×221 1122×329×247
Weight Indor/Outdoor

kg

11/27,5 11/31 13,5/45 16,5/53,5
Sound pressure level  Cooling / Heating

dBA

40/37/32/28/26 42/38/35/32/30/28/26 45/43/41/38/35/34/31 48/45/42/39/37/36/33
Technical data - Outdoor unit GWH09ACC-K6DNA1A GWH12ACC-K6DNA1D GWH18ACD-K6DNA1D GWH24ACE-K6DNA1A
Dimensions Unit (HeightxWidthxDepth)

mm

782×540×320 848×596×320 963×700×396 963×700×396
Sound pressure level  Cooling / Heating

dBA

50 52 57 56
Operation range Cooling
(Ambient Min.~Max.)

°CDB

-15~43 -15~43 -15~43 -15~43
Heating
(Ambient Min.~Max.)

°CWB

-22~24 -22~24 -22~24 -22~24
Refrigerant Type R32 R32 R32 R32

 

Funcitons:

  1. I-Feel (temperature sensor in the remote control);
  2. Automatic restart during braking and subsequent restoration of the power supply;
  3. Intelligent Defrost System;
  4. Force Defrosting;
  5. Soft start;
  6. Fastening;
  7. Automatically direct vertical airflow;