DAIKIN ALTHERMA

Floor standing air to water heat pump for heating, cooling and hot water, ideal for low energy houses

  • Perfect fit for new built as well as for low energy houses
  • Best seasonal efficiencies, providing the highest savings on running costs
  • Integrated indoor unit: all-in-one floor standing unit including the domestic hot water tank
  • Energy efficient heating and cooling system based on air to water heat pump technology
  • Flexible configuration with respect to heat emitters
  • Outdoor unit extracts heat from the outdoor air, even at -25°C

 

Technical data:

Efficiency data 

08S18CB3V
/ 08S26CB9W
+ 006CV3
08S18CB3V
/ 08S26CB9W
+ 008CV3
11S18CB3V
/ 11S26CB9W
+ 011CV3
16S18CB3V
/ 16S26CB9W
+ 014CV3
16S18CB3V
/ 16S26CB9W
+ 016CV3
Heating capacity Nom.

kW

6,00 (1) /
5,67 (2)
7,40 (1) /
6,89 (2)
11,2 (1) /
11,0 (2)
14,5 (1) /
13,6 (2)
16,0 (1) /
15,2 (2)
Cooling capacity Nom.

kW

5,88 (1) /
4,84 (2)
6,20 (1) /
5,36 (2)
12,1 (1) /
11,7 (2
12,7 (1) /
12,6 (2
13,8 (1) /
13,1 (2)
Seasonal efficiency
(сaccording to EN14825)
Domestic hot water
heating
Water heating energy efficiency class A A A A A
SEER - - - - -
Annual energy consumption

kWh

- - - - -
Space heating Seasonal space heating eff. class A++ A++ A++ A++ A+
SCOP 4,29 4,34 3,98 3,90  3,80
Annual energy consumption

kWh

- - - - -
Indoor Unit

 

08S18CB3V
/ 08S26CB9W
08S18CB3V
/ 08S26CB9W
11S18CB3V
/ 11S26CB9W
16S18CB3V
/ 16S26CB9W
16S18CB3V
/ 16S26CB9W
Dimensions Unit (HхWхD)

mm

1 732x600x728 1 732x600x728 1 732x600x728 1 732x600x728 1 732x600x728
Tank Water volume

 l

180/260 180/260 180/260 180/260 180/260
Sound pressure level Nom.

dBA

28 28 28 30 30
Outdoor Unit

 

006CV3008CV3011CV3014CV3016CV3
Dimensions Unit (HхWхD)

mm

735x832x307 735x832x307 1 345x900x320 1 345x900x320 1 345x900x320
Sound pressure level Heating / Cooling

dBA

48
49
49
50
51
50
51
52
52
54
Operation range Cooling
(Ambient Min.~Max.)

°CDB

10,0~43,0 10,0~43,0 10,0~46,0 10,0~46,0 10,0~46,0
Domestic hot water
(Ambient Min.~Max..)

°CWB

-25~35 -25~35 -20~35 -20~35 -20~35
Refrigerant *Type/Charge kg-TCO₂Eq/GWP R-410A/1,6/
3,3/2 087,5
R-410A/1,6/
3,3/2 087,5
R-410A/3,4/
7,1/2 087,5
R-410A/3,4/
7,1/2 087,5
R-410A/3,4/
7,1/2 087,5

 

 

Functions:

  • Guaranteed operation down to -25°C